12 Clinical data Myopia: The myopia clinical study included 901 eyes treated, of which 813 of 866 eligible eyes were followed for 12 months. Accountability at 3 months was 93.8%, at 6 months was 91.9%, and at 12 months was 93.9%. Of the 844 eyes eligible for the uncorrected visual acuity (UCVA) analysis of effectiveness at the 3-month stability time point, 98.0% were corrected to 20/40 or better, and 84.4% were corrected to 20/20 or better. Subjects who responded to a patient satis- faction questionnaire before and after LASIK reported the following visual symptoms at a "moder- ate" or "severe" level at least 1% higher at 3 months post-treatment than at baseline: visual fluctuations (28.6% vs. 12.8% at baseline). Long-term risks of LASIK for myopia with and without astigmatism have not been studied beyond 12 months. Hyperopia: The hyperopia clinical study included 290 eyes treated, of which 100 of 290 eligible eyes were followed for 12 months. Accountability at 3 months was 95.2%, at 6 months was 93.9%, and at 12 months was 69.9%. Of the 212 eyes eligible for the UCVA analysis of effective- ness at the 6-month stability time point, 95.3% were corrected to 20/40 or better, and 67.5% were corrected to 20/20 or better. Subjects who responded to a patient satisfaction questionnaire before and after LASIK reported the following visual symptoms as "much worse" at 6 months post-treatment: halos (6.4%); visual fluctuations (6.1%); light sensitivity (4.9%); night driving glare (4.2%); and glare from bright lights (3.0%). Long-term risks of LASIK for hyperopia with and without astigmatism have not been studied beyond 12 months. Mixed astigmatism: The mixed astigmatism clinical study included 162 eyes treated, of which 111 were eligible to be followed for 6 months. Accountability at 1 month was 99.4%, at 3 months was 96.0%, and at 6 months was 100.0%. Of the 142 eyes eligible for the UCVA analysis of effectiveness at the 3-month stability time point, 95.8% achieved acuity of 20/40 or better, and 67.6% achieved acuity of 20/20 or better. Subjects who responded to a patient satisfaction questionnaire before and after LASIK reported the following visual symptoms at a "moderate" or "severe" level at least 1% higher at 3 months post-treatment than at baseline: sensitivity to light (52.9% vs. 43.3% at baseline); visual fluctuations (43.0% vs. 32.1% at baseline); and halos (42.3% vs. 37.0% at baseline). Long-term risks of LASIK for mixed astigmatism have not been studied beyond 6 months. Wavefront-guided myopia: The wavefront-guided myopia clinical study included 374 eyes treated; 188 with wavefront-guided LASIK (Study Cohort) and 186 with Wavefront Optimized LASIK (Control Cohort). 178 of the Study Cohort and 180 of the Control Cohort were eligible to be followed at 6 months. In the Study Cohort, accountability at 1 month was 96.8%, at 3 months was 96.8%, and at 6 months was 93.3%. In the Control Cohort, accountability at 1 month was 94.6%, at 3 months was 94.6%, and at 6 months was 92.2%. Of the 180 eyes in the Study Cohort that were eligible for the UCVA analysis of effectiveness at the 6-month stability time point, 99.4% were corrected to 20/40 or better, and 93.4% were cor- rected to 20/20 or better. Of the 176 eyes in the Control Cohort eligible for the UCVA analysis of effectiveness at the 6-month stability time point, 99.4% were corrected to 20/40 or better, and 92.8% were corrected to 20/20. In the Study Cohort, subjects who responded to a patient satisfaction questionnaire before and after LASIK reported the following visual symptoms at a "moderate" or "severe" level at least 1% higher at 3 months post-treatment than at baseline: light sensitivity (47.8% vs. 37.2% at base- line) and visual fluctuations (20.0% vs. 13.8% at baseline). In the Control Cohort, the following visual symptoms were reported at a "moderate" or "severe" level at least 1% higher at 3 months post-treatment than at baseline: halos (45.4% vs. 36.6% at baseline) and visual fluctuations (21.9% vs. 18.3% at baseline). Long-term risks of wavefront-guided LASIK for myopia with and without astigmatism have not been studied beyond 6 months. Information for patients: Prior to undergoing LASIK surgery with a WaveLight Excimer Laser System, prospective patients must receive a copy of the relevant Patient Information Booklet, and must be informed of the alternatives for correcting their vision, including (but not limited to) eyeglasses, contact lenses, photorefractive keratotomy, and other refractive surgeries. Attention: Please refer to a current WaveLight Excimer Laser System Procedure Manual for a complete listing of the indications, complications, warnings, precautions, and side effects. *Trademarks are property of their respective owners. LenSx Laser Caution: United States Federal Law restricts this device to sale and use by or on the order of a physician or licensed eyecare practitioner. Indication: The LenSx Laser is indicated for use in patients undergoing cataract surgery for removal of the crystalline lens. Intended uses in cataract surgery include anterior capsulotomy, phacofragmentation, and the creation of single plane and multi-plane arc cuts/incisions in the cornea, each of which may be performed either individually or consecutively during the same procedure. Restrictions: • Patients must be able to lie flat and motionless in a supine position. • Patient must be able to understand and give an informed consent. • Patients must be able to tolerate local or topical anesthesia. • Patients with elevated IOP should use topical steroids only under close medical supervision. Contraindications: • Corneal disease that precludes applanation of the cornea or transmission of laser light at 1030 nm wavelength • Descemetocele with impending corneal rupture • Presence of blood or other material in the anterior chamber • Poorly dilating pupil, such that the iris is not peripheral to the intended diameter for the capsulotomy • Conditions that would cause inadequate clearance between the intended capsulotomy depth and the endothelium (applicable to capsulotomy only) • Previous corneal incisions that might provide a potential space into which the gas produced by the procedure can escape • Corneal thickness requirements that are beyond the range of the system • Corneal opacity that would interfere with the laser beam • Hypotony or the presence of a corneal implant • Residual, recurrent, active ocular or eyelid disease, including any corneal abnormality (for example, recurrent corneal erosion, severe basement membrane disease) • History of lens or zonular instability • Any contraindication to cataract or keratoplasty • This device is not intended for use in pediatric surgery. Warnings: The LenSx Laser System should only be operated by a physician trained in its use. The LenSx Laser delivery system employs one sterile disposable LenSx Laser Patient Interface consisting of an applanation lens and suction ring. The Patient Interface is intended for single use only. The disposables used in conjunction with ALCON instrument products constitute a complete surgical system. Use of disposables other than those manufactured by Alcon may affect system performance and create potential hazards. The physician should base patient selection criteria on professional experience, published literature, and educational courses. Adult patients should be scheduled to undergo cataract extraction. Precautions: • Do not use cell phones or pagers of any kind in the same room as the LenSx Laser. • Discard used Patient Interfaces as medical waste. AEs/complications: • Capsulotomy, phacofragmentation, or cut or incision decentration • Incomplete or interrupted capsulotomy, fragmentation, or corneal incision procedure • Capsular tear • Corneal abrasion or defect • Pain • Infection • Bleeding • Damage to intraocular structures • Anterior chamber fluid leakage, anterior chamber collapse • Elevated pressure to the eye Attention: Refer to the LenSx Laser Operator's Manual for a complete listing of indications, warnings and precautions. EW Chicago 2012 Monday April 23, 2012 12 continued from page 11 MIX13288SOV

Articles in this issue

Archives of this issue

view archives of Eyeworld Supplements - EW APR 2012 - Sponsored by Alcon